Other information:
Repair procedures
Inspection
1.Ignition "ON"
2.Manually operate the control switch and measure the voltage of blower motor.
3.Select the control switch to raise voltage until high speed.
Fan
Motor Voltage
ManualFirst speed3. ...
Repair procedures
Inspection
1.Disconnect the key warning switch connector (A) and ignition switch connector (B) from the steering column.
2.Check for continuity between the terminals.
3.If continuity is not specified, replace the switch.
Removal
1.Disconnect the negative (-) batt ...