Kia Picanto: Body Electrical System / Rear Parking Assist System
Specifications
Item
|
Specification
|
Ultrasonic sensor
| Voltage rating
| DC 12V
|
Detecting range
| 11.8 - 39.3 in (30 - 100 cm)
|
Operation voltage
| DC 9 - 16 V
|
Operation current
| 60mA Max.
|
Operating temperature
| -40 - 185°F (-40 - 85°C)
|
Operating frequency
| 52 ± 2 kHz
|
Number of sensors
| 3 EA
|
Components and components location
1. Body Control Module (BCM)
| 2. Ultrasonic sensor
|
Rear parking assist control unit function is built in BCM (Body Control Module). |
Description and operation
RPAS
(Rear Parking Assist System) is an electronic driving aid that warns
the driver to be cautious while parking or driving at low speed. The
sensor uses ultrasonic waves to detect objects within proximity of the
vehicle.
RPAS
consists of four RPAS sensors which are detecting the obstacles and
transmit the result separated into three warning levels, the first,
second and third to BCM by Lin communication. BCM decides the alarm
level by the transmitted communication message from the slave sensors,
and then operates the buzzer or transmits the data for display.
System Operation Specification.
1. | INIT mode (1) | System initializing time is 500ms after IGN1+ R Gear. |
(2) | RPAS recognizes LID and sets the sensor ID up during initialization. |
(3) | RPAS activates each sensor and then executes the diagnosis after finishing initialization of BCM |
(4) | If the diagnosis is completed and sensor does not send an error message, “RPAS Startling Buzzer” is normally worked. |
(5) | If failure is received from any sensors, R-PAS Starting Buzzer” does not work but the failure alarm is operated for a moment. If you have display option, warning sign is also shown on it. |
(6) | Buzzer for sensor failure is operated once, but the sensor failure state is shown in display until the failure is repaired. |
|
2. | NORMAL Mode (1) | Lin communication starts and keeps the routine after IGN1 ON+R gear |
(2) | BCM
sends a message once to each sensor for operating request to check the
initial status of the system and four sensors response all at once. At
this time, if there is no problem, the alarm starts after 500 ms of R
gear shifting at 300 ms intervals. |
(3) | After initialization, normal mode starts 100ms later after finishing alarm output. |
(4) | Alarm for obstacles is divided into 3 levels. The first and second are intermittent sound, and the third alarms continuously |
(5) | The efficient vehicle speed of RPAS operation is below 10Km/h. |
(6) | Refer to ‘Digital PAS Project LIN communication’ for the more detailed communication specification. |
|
Sensing Area
1. | Measurement condition – PVC pole (diameter 75mm, length 1m), normal temperature |
2. | Distance range detected objects (Measured directly in front of sensor) 61cm(24.0in) - 120cm(47.2in) : ± 15cm(5.9in) 31cm(12.2in) - 60cm(23.6in): ± 15cm(5.9in) Less than 30cm(11.8in) : ± 10cm(3.9in) |
Horizontal Sensing Area
Vertical Sensing Area
Distance Measurement
Transmission and Reception are executed with one sensor
(RL, RC, RR each sensor execution)
(RC → RL, RC → RR Execution in order)
With two or three sensors, one of them sends the transmission and the others get the reception.
Direct and Indirect Measurement at once |
With two or three sensors, the one sensor performs both transmission and reception, and the others perform only reception.
RPAS alarm system
When
the RPAS sensor detects the object, warning is operated by audible
alarm device as like buzzer. RPAS sensor sends data to BCM via LIN
communication and BCM implements audible warning for each RPAS SENSOR by
priority. And it performs a role of gateway only when it sends visible
alarm device such as Cluster.
–
| Sensor
buzzer/display information processing method of BCM In case of RL/RR
sensor information, the BCM handles each sensor information directly
about Display and buzzer output function. Buzzer output of CL/CR
sensor, BCM handles center combination information by priority both
sensor. |
System Operation Spec
When
the system has the power (after IGN ON and R gear), MICOM checks every
sensor channel. In case it finds any error, it gives off the buzzer for
300ms after 500ms.If an error is found even in a sensor, it gives off
the buzzer corresponding to the faulty sensor, instead of initial
starting alarm. The operation to enter the normal mode is as follows.
With the R gear put in the car, the system is operated as follows.
With the R gear released, the system is operated as follows.
※ The acceptable error range on waveform is ±10%.
Alarm Output Specification classified by distance between sensors
Condition logic according to priority of alarm level is as below. (the identical sensor)
*α value definition
1. | low priority sensor off : α = 0ms |
2. | low priority sensor is 1st warning level : α < 340ms |
3. | low priority sensor is 2nd warning level : α < 170ms |
*β value definition
1. | low priority sensor is 1st warning level : β = 1700ms |
2. | low priority sensor is 2nd warning level : β = 1700ms |
3. | low priority sensor is 3rd warning level : β = 700ms |
Alarm control by sensing distance is as follows.
1. | First warning area (31.9 in (81 cm) - 47.2 in (120 cm) )
|
2. | Second warning area (16.1 in (41 cm) - 31.5 in (80 cm) )
|
3. | Third warning area (less than 15.7 in (40 cm))
|
Visible Alarm Indicator Specification
When the gear shifts to R, the cluster controls the indicator as the following picture.
When
the system detects an object, it immediately turns on the indicator.
If an object disappears while the RPAS detecting operation, the
indicator remains on for 2 sec. before being turned off.
(But when it turns third step alarm to No alarm status, it lights third step alarm for two second and turns out.)
–
| It shows only the detecting position of obstacles. |
–
| In third level alarm, indicator flickers at intervals of a second. |
–
| In normal alarm mode, integrated display of RCR/RCL |
Communication Standard
This section defines the communication between RPAS and BCM.
RPAS
send a detecting result of object and sensor diagnosis result to BCM
according to this document, and BCM takes a role to issue an alarm.
Indicator
shows the transmitted position and alarm data, in the alarm mode, it
finds the nearest DATA and alarms the nearest DATA first.
(Ex. In case, RL isthe first-step alarm and RR is the third step, RR alarm has priority.)
Repair procedures
Inspection
1.In the body electrical system, failure can be quickly diagnosed by using the vehicle diagnostic system (KDS/GDS).The diagnostic system (KDS/GDS) provides the follo ...
Components and components location
Components
Repair procedures
Removal
1.Disconnect the negative (-) battery terminal.
2.Remove the rear bumper assembly.
(Refer to B ...
Other information:
Components and components location
Component Location
1. Back view camera 2. AVN head unit 3. steering angle sensor
Description and operation
Description
1. To
display back of the vehicle to assist the driver, it receives vehicle
rearside image signal from the rearview ...
Repair procedures
Removal
1.Disconnect the negative (-) battery terminal.
2.Remove the steering column upper and lower shrouds after loosening the screws.
(Refer to Body - "Steering Column Shroud Panal")
3.Disconnect the wiper switch / washer switch connector (A).
4.Rem ...